Report 00024

Defects or Issues Identified

Bay 03 - No fall protection in cell 07 – Portside ladder hatch cover - half of the ladder hatch is missing & other half wont close due to handrail in the way – Centre platform ladder hatch is bent/broken & has no fall protection

Bay 05 - Aft Cell 09 Stbd No Fall protection - Rusted and unsafe walkways - Hatchcover above ladder is too rusted to stand on

Bay 11 – Aft Walkway is rusted bent and broken - Fall protection on outside cells is inadequate as there are large gaps.

Bay 13 – Cell 12 fall protection is inadequate as the temporary rails are, rachet straps they used for lashing the boat on the

bay aft (needs to be welded rails or staunions with wire rope rails etc)

Bay 15 – Outside cell fall protection is inadequate Lighting towers being used as railings are not high enough and there are large gaps either side.

Bay 18 – Manual pins down below requires personel to work in hatch and remove pins which may create working at heights issues.

Bay 27 – Aft entire walkway is obstructed by manual spreaders, - Manual spreader blocks access to ladder hatchway portside - Rusted, bent & broken walkway very unsafe (near cell 10 and also near cell 5)

Bay 31 - Outside cell fall protection is inadequate Lighting towers being used as railings are not high enough and there are large gaps either side.

Bay 33 - Outside cell fall protection is inadequate.

Bay 35 - Outside cell fall protection is inadequate large gap between boxes and handrails. - Portside outside cell protection – rails are broken and missing

Bay 42 – There are no provisions for staunchions when there are no boxes there fwd & aft. - Outside cell fall protection is inadequate with large gaps between rails and boxes - Aft ladder Hatchway cover is rusted and seized open The walkways are too narrow at the following bays (Do Not comply with MO32) due to Hatchlid guides: 07, 15 and 23. There are no Handgrips present at the top of ladders at the following bays: 01, 03, 07, 15, 19, 23, 31, There are no clips securing the steel grated walkways at the following bays: 01, 05, 07, 11, 15, 17, 19, 23, 27, 31. Ladder Hatchcovers that are too rusted & won't close (creating fall hazard) STARBOARD SIDE - Bays 13/15 centre platform (cell 11), 15 Aft, 17/19 Centre, 19 Aft, 21/23 Centre, 25/27 Centre, 27 aft, 29/31 centre, 33/35 centre, PORT SIDE 9/11 Centre (Cell 12), 11 Aft, 13/15 centre, 15 Aft, 23 Aft, 27 Aft, 31 Aft.